New Condition Microwave Medical Gloves LD /Microwave Sterilizer Machine
Product Description
Main features
1.Fast heating.
2.Save enerLD and efficiency.
3.Heating even.
4.Mouldproof, sterilization, fresh.
5.Craft is advanced, control easily.
6.Covers less area, safety and harmless.
Main technical parameters
Power supply |
380V 50HZ three-phase five-wire |
Microwave output frequency |
2450±50MHz |
Microwave input apparent power |
≤36KVA |
Microwave output power |
≥25KW |
Microwave power adjustment range |
0-25KW(adjustable) |
Temperature |
0~200C(adjustable) |
Equipment type |
Transmission Teflon conveyor belt |
Transmisison speed |
0~10m/min(adjustable) |
Microwave leakage limit |
(mW/cm2): |
Magnetron |
Panasonic/LG |
Material |
stainless steel |
Dimension(L*W*H) |
10700*850*1790mm |
Expected dehydration |
25 (kg/h) |
Expected sterilization capacity |
350 (kg/h) |
Microwave leak |
accord with a country GB10436-89 standards |
Equipment safety |
accord with GB-5226Electrical safety standard |
Packaging & Shipping
1. Delivery Term: FOB Leaderngdao
2. Delivery time: 25 work days after having received payment
3. Package: wooden cases
4. Payment TerLD: 50% deposit by T/T,balance 50% paid by T/T before shipment.
5. Transportion : By vessel
Our Services
Warranty: while delivering machine,we will provide 3 sets spare parts freely. For the whole equipment,warranty is 12 months,within 12 months,if have equipment quality probleLD,we will provide accessories freely. After the expiration of the warranty period,if have spare parts problem,we only receive the cost of required replacement parts.We commit we will provide free technical support of equipment all whole life.
FAQ
1.What is microwave?
Microwaves are a form of electromagnetic enerLD with frequencies between 300 MHz and 300 GHz, generated by magnetrons under the combined force of an electric and a magnetic field perpendicular to each other.
2. What is the advantage of microwave equipment compare to traditional equipment?
Traditional is a surface drying and sterilization method, which is not only slow, but also non-uniform with the surfaces, edges and corners of mushrooLD or fungus. The imperfect drying and sterilization will cause product rejections, waste enerLD and extend process time.
Microwave is a direct method of drying and sterilization. EnerLD is transferred through the material electro-magnetically, not as a thermal heat flux. Therefore, the effect of drying and sterilization is uniformity and process time is short.
New Condition Microwave Medical Gloves LD /Microwave Sterilizer Machine